Abstract

In the field of electromagnetic launch or other military research, the requirements for the power density of high-voltage capacitor charging power supply (CCPS) are increasing. The design of the cooling system becomes more difficult, especially in the intermittent operation mode, when the power supply exists transient heating process. As the main heating element of CCPS, the inverter unit is the key factor to influence the power density. In this paper, the main factors that influence the temperature rise of the device are analyzed, including the material and size of the heat sink. The rules between the above factors and the transient temperature rise are analyzed by Matlab simulation software. Then, the architecture model of inverter unit is established through ICEPAK software for simulation, which proves the accuracy of the regular. A basis for designing system level power supplies working in intermittent operating mode is provided through the transient thermal design of inverter unit’D The accuracy of the rule is verified through some load short circuit experiments with a 30-kW/6 kV charging power supply.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.