Using the shock wave technique, radial distributions of gas temperature have been measured in cylindrical, wall stabilized, arc columns under both steady state and transient conditions. The arc atmosphere was air and the current range 0·5-100 A. The transient measurements included the case of free recovery following sudden current interruption.The temperature profiles have been used in conjunction with published electrical conductivity data to determine electrical conductance values and these show good agreement with direct electrical measurements and theory. This result confirms that the arc plasma is in approximate thermal equilibrium so that the column behaviour may be described solely in terms of thermal processes.The importance of natural radial flow under transient conditions has been estimated by calculating flow velocity profiles from the measured temperature distributions and published gas density data. The results are in good agreement with theory, and show the increasing importance of the radial flow at higher currents.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.