Abstract

Exit gas temperature responses of the counterflow rotary regenerator are found for a unit step increase of the inlet temperature of either gas. An analytic solution applicable during the first part of the transient shows that the responses cannot be smooth. The overall response is found by dividing the regenerator disk into pie-shaped segments and approximating the area-mean gas temperature leaving a segment as the temperature of the gas leaving a small regenerator located at the center of the segment. The method is shown to give good accuracy and is in agreement with predictions of the analytic solution.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.