Abstract
Transient behavior of small gas bubbles in a liquid set into violent motion by ultrasonic pressure waves is of interest because of widespread use of microsecond pulses in diagnostic ultrasound. Such pulses contain only a few pressure cycles and the transient pulsations of bubbles set in motion by such pulses would determine the bubble‐ultrasound interaction. A computer study has been made to obtain a global representation of the pulsation amplitudes R(t) of small gas bubbles (nulcei) in water during the first few cycles of a cw ultrasonic pressure. One objective was to obtain a better understanding of cavitation phenomena where many nuclei with initial radii from 0.1 to 20 μm are set in motion at pressures ranging from 0.5–5 bars and at frequencies from 0.5–10 MHz. Results allowed construction of surfaces showing the relative bubble amplitude R/Rn, as a function of Rn, and of the time t/TA, where TA is the acoustic period. One finding is that, in the range of peak pressures found in diagnostic pulses, transient cavities would be generated during the first pressure cycle from nuclei with initial radii as small as a few microns (μm). [Research supported by NIH.]
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.