Abstract

A transient phase-measuring technique that uses a self-pumped phase-conjugate mirror as an optical novelty filter is presented. A change in the reflectivity of the mirror as a function of a change in the incident wave front permits the transient measurement of a two-dimensional phase distribution. This method allows us to investigate fast processes using media with slow response. A simple theoretical model explains the experimental results with sufficient accuracy. The results can be used for the calibration of the measuring system. The described method is used for the measurement of a temporally varying wave front.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.