Abstract

The transient performance of an air-cooled condensing heat exchanger in a long-term passive cooling system was evaluated under a decay heat load modeled by the ANS-73 curve. An experiment was conducted in a 1/2500-volume scaled-down model of the emergency cooldown tank (ECT) of the system-integrated modular advanced reactor (SMART). It was confirmed that the scaled design requirement of cooling capacity of the air-cooled condensing heat exchanger was well satisfied under the decay heat load. It was also confirmed that the water level in the emergency cooldown tank was maintained continuously for longer than 72h by the collection of steam in the air-cooled condensing heat exchanger under the decay heat load.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.