Abstract

Improvement of a new design for a capillary pumped loop (CPL) ensuring high-dissipation electronics cooling in ground transportation has been carried out over recent years. Experimental studies on the hybrid loop, which share some characteristics with the standard CPL and loop heat pipe (LHP), have underlined the sizable potential of this new system, particularly with regard to its upcoming industrial applications. In order to obtain a reliable tool for sizing and design of this CPL for terrestrial applications (CPLTA), the present transient thermohydraulic modeling has been developed. Based on the nodal method, the model's originality consists of transcribing balance equations under electrical networks by analogy. The model's validation is provided by experimental results from a new CPLTA bench with three parallel evaporators. Large-scale numerical evaluation of loop behavior in a gravity field with a single evaporator shall facilitate understanding of the different couplings between loop parts. In addition, modeling of a multi-evaporator loop is introduced and compared with recent experimental results.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.