Abstract

This paper addresses the specific issues of transient leak detection in crude oil pipelines. When a leak occurs immediately after pumps are switched on or off, the pressure wave generated by the transients dominates the pressure wave that results from the leak. Traditional methods have failed to detect such leaks. Over the years, NWO has developed and implemented various leak detection systems both in-house and by commercial vendors. These systems work effectively under steady-state conditions but they are not able to detect leaks during transients. As it is likely for a leak to develop during transients, NWO has decided to have the ATMOS Pipe statistical leak detection system installed on their pipelines. This paper describes the application of this statistical system to two crude oil pipeline systems. After addressing the main difficulties of transient leaks, the field results will be presented for both steady-state and transient conditions.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.