Abstract

Improvements of high voltage design criteria and quality assurance for ITER coils are indispensable taking into account the problems occurred during high voltage tests of the ITER TF model coil. One important aspect to consider is the transient electrical behaviour because fast changes of voltages may cause local overloading and destruction of the insulation system. This paper will present the calculation of the terminal voltages within the ITER TF coil system and the voltage stress of the insulation within an individual ITER TF coil for the fast discharge and two fault cases. Proposals for the high voltage tests are discussed based on the calculated voltage stress of the two fault cases and the experiences gained during the ITER TF Model Coil test to ensure appropriate dielectric quality of the ITER TF coils.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.