Abstract

A requirement for bunch coalescing and bunch rotation for antiproton production in the Fermilab Main Ring is that the net rf voltages be reduced below ~1 kV. At high beam intensities, the fields generated by the beam in a single pass through the rf cavities will exceed this limit. The new compensation systemmonitors the component of the beam current at the fundamental rf frequency as a function of time. This information is then delayed by a single turn and fed back into the high level rf system to cancel the beam-induced fields. The system has compensated the beam-induced voltage generated by a single booster batch to 5% of its initial value.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.