Abstract
A new approach for identi cation of the S-shape region of pump turbines by means of transient tests is presented. The behavior of pump turbines is characterized by the S-shape region that is passed during load rejection. The mechanisms within the S-shape region are still part of basic research. Beside the known Thoma number dependency, further non-linear effects in terms of a hysteresis loop in the S-shape region are suspected. Since the S-shape region is passed in both directions during load rejection a hysteresis behavior would in uence the water way dynamics. The common approach by measuring various steady points is not able to capture this non-linear effect. Therefore, a transient approach for model tests is investigated. Within this paper the transient model test procedure is described and the results of the model test are shown. Since the transient behavior is superimposed by high frequent pressure uctuations, special focus is on the evaluation of the measurement data. Finally, the in uence of the hysteresis behavior on the simulation results of water way dynamic system is shown.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: IOP Conference Series: Earth and Environmental Science
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.