ABSTRACTThe paper derives closed-form expressions for transient and steady-state operation of a DC–DC converter with single switched capacitor. To this end, the result of each switching is considered as a point in the iterative process, and the function between the points is reconstructed. As opposed to the commonly accepted approach, when each of the topologies is approximated by a first-order circuit, the proposed analysis is carried out for second-order circuits. This allows obtaining the waveform of output voltage ripple and paves the way to more accurate calculation of equivalent resistance. The obtained analytical expressions were verified by simulations and an excellent agreement between the results was found.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.