Abstract

An improved method is used capable of calculating any form of generator transients. In this method, based on a two-dimensional model, solid conducting parts of the rotor are represented by multiple thin conducting layers. The resulting non-linear differential equations are solved numerically for the recently proposed new rotor arrangement with independently rotatable (free) outer rotor. The results are compared with the previously accepted arrangement having rigid connection of outer to inner rotor showing that the free outer rotor arrangement greatly relieves the inner rotor of transient torques and that its steady-state stability, although inferior to the rigidly fixed outer rotor configuration, is nevertheless quite adequate: it compares very favourable with that of the conventional generator, being markedly superior on underexited operation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.