Abstract

In a tube-type condenser, involving complete condensation, small changes in the inlet vapor flowrate momentarily cause very large transient surges in the outlet liquid flowrate. Experimental data are presented which indicate that compressibility effects tend to attenuate the amplitude of these flow surges. The system mean void fraction model was extended to include compressibility effects and its predictions are shown to agree well with experimental data. The model is further extended to predict the response characteristics to an oscillatory inlet flowrate and compared with predictions based upon the drift-flux model.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.