Abstract
Despite current blood safety measures, transfusion recipients can experience transfusion-related adverse reactions. Monitoring these reactions can aid in understanding the effectiveness of current transfusion safety measures. Data from the National Healthcare Safety Network Hemovigilance Module were used to quantify adverse reaction risk. Facilities reporting at least one month of transfused blood components and transfusion-related adverse reactions during January 2013-December 2018 were included. Adverse reaction rates (number per 100,000 components transfused) were calculated for transfused components stratified by component type, collection, and modification methods. During 2013-2018, 201 facilities reported 18,308 transfusion-related adverse reactions among 8.34 million blood components transfused (220/100,000). Adverse reactions were higher among apheresis (486/100,000) and pathogen-reduced platelets (579/100,000) than apheresis red blood cells (197/100,000). Allergic reactions (41%) were most common. There were 23 fatalities and 9% of all adverse reactions were serious (severe, life-threatening, or fatal). Reactions involving pulmonary complications (transfusion-associated circulatory overload, transfusion-related acute lung injury and transfusion-associated dyspnea) accounted for 35% of serious reactions but 65% of fatalities. Most (76%) of the 37 transfusion-transmitted infections were serious; none involved pathogen-reduced components. One in 455 blood components transfused was associated with an adverse reaction although the risk of serious reactions (1 in 6224) or transfusion-transmitted infections (1 in 225,440) was lower. Some serious reactions identified were preventable, suggesting additional safety measures may be beneficial. Higher reaction rates identified among pathogen-reduced platelets require further study. These findings highlight the importance of monitoring reactions through national hemovigilance to inform current safety measures and the need for strategies to increase healthcare facility participation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.