Abstract

Use of high-temperature superconducting (HTS) windings may soon turn power transformers into compact high-performers on good terms with the environment. The potential for HTS transformers is being examined in major design and hardware development programs by several teams of engineers and scientists worldwide. The team to which the authors belong is led by Waukesha Electric Systems. The Waukesha-led team has conducted a series of reference designs concentrating mostly on a 30-MVA, 138-kV/13.8-kV transformer rating. This rating is representative of a medium power transformer class foreseen as comprising about half of all US power transformer sales in the next two decades. Two of these designed are compared with a 30-MVA conventional oil-filled transformer typical of this class. Each uses a different commercially successful and reliable type of refrigeration. Since reliable operation is paramount, both transformers are designed to have a several-day on-board refrigeration reserve that lets them operate continuously with no interruption of service to customers.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.