A method was described for subtyping transferrin derived from human bloodstains. Bloodstain cuttings were extracted in 0.5% ferrous ammonium sulfate. The extracts were subjected to ultrathin-layer polyacrylamide gel isoelectric focusing. After isoelectric focusing, transferrin was detected by silver staining. This method permitted the successful typing of Tf in 6-month-old blood stains maintained at −20°C and room temperature and 3-month-old bloodstains maintained at 37°C.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.