Abstract

Based on the experiments on 10 specimens of steel fiber reinforced high strength concrete three-pile caps with the ratio of the model to the real of 1:5, the developing of cracks and failure of caps were described, the transfer mechanism of pile caps was analyzed in detail and the principle of space truss model of the thick three-pile cap was proposed. The test results suggested that the destruction of thick pile cap belongs to punching or shear failure, which is different from that of the general bending member.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.