Abstract

Transfacet screw fixation is a biomechanically effective way of fusing the subaxial cervical spine. The technique used by this author is described. With the patient in prone position, a conventional posterior exposure of the cervical spine is done. The entry point used by this author is 2 mm above the middle of the lateral mass without any lateral angulation. Under fluoroscopic guidance the facet is drilled until all the four cortical surfaces are purchased. Then the depth is measured to assess the length of the screw required. This is followed by tapping and screw insertion both of which are done under fluoroscopic control. All screws are placed prior to laminectomy to decompress the cervical cord. This is a simple, inexpensive and biomechanically effective way of stabilizing the subaxial cervical spine.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.