Abstract

BackgroundIt is unclear if the WATCHMAN device (Boston Scientific, St. Paul, Minnesota) can be implanted without contrast to prevent complications in patients with advanced chronic kidney disease (CKD) or contrast allergy.ObjectiveThe efficiency and safety of WATCHMAN implantation under transesophageal echocardiography (TEE)-guidance and fluoroscopy without contrast use.MethodsThis was a retrospective single-center study at Albany Medical Center between June 2016 and June 2019. Consecutive procedure notes for all WATCHMAN devices implanted between June 2016 and June 2019 were screened to identify patients who did not receive contrast. Patients with incomplete information on the calculation of the 'Congestive heart failure, Hypertension, Age [>75 years], Stroke, Diabetes mellitus, Vascular disease, Age [65 to 74 years], Sex category' (CHA2DS2VASc)/'Hypertension, Abnormal renal/liver function, Stroke, Bleeding history, Labile international normalized ratio, Elderly, Drugs/alcohol' (HAS-BLED) score and reason(s) precluding safe contrast use were excluded. Efficiency was measured as i) accuracy of device size estimation based on TEE-measured left atrial appendage (LAA) dimensions were determined by the need to change the size of the device initially selected, ii) number of implantation attempts, irrespective of change in device size, iii) whether more than one device was used secondary to inaccurate initial size estimation or other procedural complexities, and iv) successful LAA seal on TEE immediately and 45-days post-implantation (peri-device leak of < 5 mm by color Doppler). Procedure-related complications, immediate and delayed (0-45 days), were recorded.ResultsTwelve patients received WATCHMAN without contrast. The mean age was 79.2 years, with male predominance (n=8). The mean CHA2DS2VASc and HAS-BLED scores were 5.50 (+/-1.24) and 4.08 (+/-1.08), respectively. Contrast was avoided because of a history of CKD stage IV (n=5), rapidly progressive CKD stage III (n=1), and contrast allergy (n=6). In 11 out of 12 patients, initial TEE-based device size estimation was accurate with successful implantation at the first attempt. One patient required a change in initial device size and, therefore, required a second attempt for successful implantation. There was no peri-device leak immediately post-implantation in any patient; only one patient had a significant device leak on day 45 TEE requiring continuation of anticoagulation for four months until a successful device seal. There were no immediate or late complications up to 45-days post-implantation.ConclusionOur experience shows no significant compromise in the efficiency and safety of the WATCHMAN implantation without contrast in patients with advanced CKD or a contrast allergy.

Highlights

  • IntroductionSince the Prospective Randomized Evaluation of the Watchman LAA Closure Device In Patients With Atrial Fibrillation Versus Long Term Warfarin Therapy (PREVAIL) study demonstrated its noninferiority to warfarin for thromboembolism prevention in non-valvular atrial fibrillation, left atrial appendage (LAA) occlusion is increasingly offered to patients who are unable to tolerate long-term anticoagulation [1]

  • Efficiency was measured as i) accuracy of device size estimation based on transesophageal echocardiographic (TEE)-measured left atrial appendage (LAA) dimensions were determined by the need to change the size of the device initially selected, ii) number of implantation attempts, irrespective of change in device size, iii) whether more than one device was used secondary to inaccurate initial size estimation or other procedural complexities, and iv) successful LAA seal on TEE immediately and 45-days post-implantation

  • In 11 out of 12 patients, initial TEE-based device size estimation was accurate with successful implantation at the first attempt

Read more

Summary

Introduction

Since the Prospective Randomized Evaluation of the Watchman LAA Closure Device In Patients With Atrial Fibrillation Versus Long Term Warfarin Therapy (PREVAIL) study demonstrated its noninferiority to warfarin for thromboembolism prevention in non-valvular atrial fibrillation, left atrial appendage (LAA) occlusion is increasingly offered to patients who are unable to tolerate long-term anticoagulation [1]. How to cite this article Saad Shaukat M, Patel H, Alimohammad R, et al (May 31, 2020) Transesophageal Echocardiography-Guided WATCHMAN Implantation Without Contrast Use: A Three-Year, Single-Center Experience. Over one-third of patients with an implanted LAA occlusion device have chronic kidney disease [3]. We report our experience performing LAA occlusion with the WATCHMAN (Boston Scientific, St. Paul, Minnesota) device, guided by TEE and fluoroscopy without contrast administration. Minnesota) device, guided by TEE and fluoroscopy without contrast administration It is unclear if the WATCHMAN device (Boston Scientific, St. Paul, Minnesota) can be implanted without contrast to prevent complications in patients with advanced chronic kidney disease (CKD) or contrast allergy

Methods
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.