Abstract
Both retrograde femoral and subclavian artery catheterization techniques have been described as the most common methods for the implantation of the Medtronic CoreValve percutaneous aortic valve (Medtronic Inc, Minneapolis, Minn). The subclavian artery has been shown to be a safe and effective alternative access route in patients with unfavorable femoral access. Of the patients who are identified as candidates for subclavian artery access, a subset possess a patent left internal thoracic artery to left anterior descending artery. This patent left internal thoracic artery presents an additional anatomic and clinical variable that must be taken into consideration to ensure procedural safety and efficacy. We describe the Medtronic CoreValve percutaneous aortic valve implantation using the subclavian arterial approach in patients with a patent left internal thoracic artery and report our study's findings. The CoreValve percutaneous aortic valve is a self-expandable nitinol-based frame with a porcine pericardial valve. The subclavian access was created by a small infraclavicular surgical incision to expose the artery. Rapid ventricular pacing was used to reduce cardiac output to perform the balloon aortic valvuloplasty via a 12F sheath inserted into the subclavian artery. An 18F sheath was then inserted into the artery down into the ascending aorta and used for introduction of the delivery catheter and implantation of the percutaneous aortic valve. With the use of this method, 19 patients (76 ± 13 years) whose surgical risk was deemed excessive because of severe comorbidity and in whom transfemoral catheterization was considered unfeasible or at risk of severe complications have received implants. Subclavian artery or left internal thoracic artery injury did not occur in any patient. Two deaths occurred. One patient died of right coronary artery occlusion during the procedure, and one patient died 48 hours after the procedure as the result of a tamponade after the temporary pacemaker wire ablation. This initial experience suggests that subclavian transarterial aortic valve implantation in patients with a patent left internal thoracic artery to left anterior descending artery is feasible and safe with satisfactory short-term outcomes.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: The Journal of Thoracic and Cardiovascular Surgery
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.