Abstract

BackgroundIn specific patients with severe mitral regurgitation (MR), mitral valve (MV) pathology is unique and requires creative transcatheter repair techniques. This study aimed to evaluate the feasibility and safety of a new transcatheter MV repair technique, using occluder devices in symptomatic high-surgical-risk patients with severe MR, either due to MV leaflet (MVL) perforations or due to post-clips residual MR, and to report on their 6-month outcomes. MethodsThe study enrolled all high-risk patients with severe MR due to MVL perforations and post-clips residual MR who underwent transcatheter MV repair using occluder devices, from November 2016 to August 2019. ResultsThe study enrolled 16 patients; 9 (56.25%) with MVL perforations and 7 (43.75%) with post-MitraClip (Abbott Laboratories, Abbott Park, Illinois) residual MR, with a mean age of 55.75 ± 16.69 years. Mean perforation/jet diameters were 5.75 ± 1.67 and 6.5 ± 1.93 mm, and the mean 3D-vena contracta area was 0.54 ± 0.14 cm2. Perforations were crossed retrograde (transaortic in 7 [43.75%] patients and transapical in 2 [12.5%] patients), and post-MitraClip devices residual jets were crossed antegrade (transvenous/transseptal). Six (37.5%) patients required arteriovenous loop formation for device deployment, that was antegrade transvenous/transseptal in 13 (81.25%) patients and retrograde transapical in 3 (18.75%) patients. Devices used were Amplatzer-ASO in 10 (62.5%) patients and Amplatzer-VP-II in 6 (37.5%) patients. Mean procedural and fluoroscopy times were 55.13 ± 16.24 and 16.25 ± 4.03 ​minutes, respectively. Patients passed successfully, without MV gradient change or device-related complications. ConclusionsTranscatheter MV repair of MVL perforations/post-clips residual MR is a new, feasible, and safe technique for high-surgical-risk patients.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call