Abstract

BackgroundReal-world applicability of the COAPT (Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients with Functional Mitral Regurgitation) randomized controlled trial (RCT) has been debated because of careful patient selection and the contrasting results of the MITRA-FR (Multicentre Study of Percutaneous Mitral Valve Repair MitraClip Device in Patients with Severe Secondary Mitral Regurgitation) RCT. ObjectivesThe COAPT-PAS (COAPT Post-Approval Study) was initiated to assess the safety and effectiveness of the MitraClip in patients with secondary mitral regurgitation (SMR). MethodsCOAPT-PAS is a prospective, single-arm, observational study of 5,000 consecutive patients with SMR treated with the MitraClip at 406 U.S. centers participating in the TVT (Transcatheter Valve Therapy) registry from 2019 to 2020. The 1-year outcomes from the COAPT-PAS full cohort and the COAPT-like and MITRA-FR–like subgroups who met RCT inclusion/exclusion criteria are reported. ResultsPatients in the COAPT-PAS had more comorbidities, more severe HF and functional limitations, and less guideline-directed medical therapy than those in the COAPT or MITRA-FR RCTs. Patients in the COAPT-PAS full cohort and the COAPT-like (n = 991) and MITRA-FR–like (n = 917) subgroups achieved a 97.7% MitraClip implant rate, a similar and durable reduction of mitral regurgitation to ≤2+ at 1 year (90.7%, 89.7%, and 86.6%, respectively), a large improvement in quality of life at 1 year (Kansas City Cardiomyopathy Questionnaire +29 COAPT-PAS, +27 COAPT-like, and +33 MITRA-FR–like), faster procedure times, similar or lower clinical event rates compared with the RCTs’ MitraClip arms, and lower clinical event rates than the RCTs’ guideline-directed medical therapy only arms. One-year heart failure hospitalizations was 18.9% in COAPT-PAS, 19.7% in COAPT-like compared with 24.9% in COAPT-RCT, and 28.7% in COAPT-PAS-MITRA-FR–like compared with 47.4% in MITRA-FR-RCT. ConclusionsThis large, contemporary, real-world study reinforces the safety and effectiveness of the MitraClip System in patients with SMR, including those who met the COAPT or MITRA-FR RCT inclusion/exclusion criteria and patients excluded from the RCTs.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.