Abstract

Nowadays, transcatheter device closure of an atrial septal defect (ASD) is a standard approach in children. Potential early and long-term side effects or complications related to the metal framework of the devices are a known issue. A bioresorbable device such as the Carag Bioresorbable Septal Occluder™ (CBSO) could resolve such complications. Material and Results. The Carag Bioresorbable Septal Occluder™ (CBSO; Carag AG, Baar, Switzerland) is a self-centering double disk, repositionable, and retractable device with a bioresorbable framework (polylactic-co-glycolic acid), which is almost completely resorbed by 18-24 months postimplantation. This manuscript reports the four first-in-child ASD device closures using a CBSO. The patients' age was median (IQ1-IQ3), 4.5 years (4-7.25). Weight was 21.3 kg (17.6-32.7). We demonstrated procedural feasibility and safety. Effective defect closure with the device was 100%. Echocardiographic measurements of the thickness of the interatrial septum did not show any relevant increase over a 12-monthfollow-up period. There were no residual defects found after the procedure or later during the resorption process. The patients showed no evidence of any local or systemic inflammatory reaction. The CBSO device system could offer a new treatment option for transcatheter ASD device closure in the pediatric and adult fields. In our first-in-child experience, it was effectively and safely implanted. During the first 12 months of follow-up, no complications occurred.