Abstract

The aim of this study was to compare outcomes after transfemoral transcatheter aortic valve implantation with the Medtronic CoreValve (MCV) versus the Edwards SAPIEN/SAPIEN XT transcatheter heart valve (ESV) for severe aortic stenosis. No large matched comparison study has been conducted so far evaluating both commercially available devices. The data from databases of 4 experienced European centers were pooled and analyzed. Due to differences in baseline clinical characteristics, propensity score matching was performed. Study objectives were Valve Academic Research Consortium outcomes at 30 days and 1 year. In total, 793 patients were included: 453 (57.1%) treated with the MCV and 340 (42.9%) with the ESV. After propensity matching, 204 patients were identified in each group. At 30 days, there were no differences in all-cause mortality (MCV, 8.8% vs. ESV, 6.4%; hazard ratio [HR]: 1.422; 95% confidence interval [CI]: 0.677 to 2.984; p = 0.352), cardiovascular mortality (MCV, 6.9% vs. ESV, 6.4%; HR: 1.083; 95% CI: 0.496 to 2.364; p = 0.842), myocardial infarction (MCV, 0.5% vs. ESV, 1.5%; HR: 0.330; 95% CI: 0.034 to 3.200; p = 0.339), stroke (MCV, 2.9% vs. ESV, 1.0%; HR: 3.061; 95% CI: 0.610 to 15.346; p = 0.174), or device success (MCV, 95.6% vs. ESV, 96.6%; HR: 0.770; 95% CI: 0.281 to 2.108; p = 0.611). Additionally, there were no differences in major vascular complications (MCV, 9.3% vs. ESV, 12.3%; HR: 0.735; 95% CI: 0.391 to 1.382; p = 0.340) or life-threatening bleeding (MCV, 13.7% vs. ESV, 8.8%; HR: 1.644; 95% CI: 0.878 to 3.077; p = 0.120). MCV was associated with more permanent pacemakers (22.5% vs. 5.9%; HR: 4.634; 95% CI: 2.373 to 9.050; p < 0.001). At 1 year, there were no differences in all-cause (MCV, 16.2% vs. ESV, 12.3%; HR: 1.374; 95% CI: 0.785 to 2.407; p = 0.266) or cardiovascular (MCV, 8.3% vs. ESV, 7.4%; HR: 1.145; 95% CI: 0.556 to 12.361; p = 0.713) mortality. No differences between the 2 commercially available transfemoral transcatheter aortic valve implantation devices were observed at the adjusted analysis in Valve Academic Research Consortium outcomes except for the need for permanent pacemakers with the MCV.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.