Abstract
Aortic valve stenosis due to chronic rheumatic heart disease remains prevalent in the Asia-Pacific region. Because of the lack of substantial calcification that can anchor a transcatheter aortic valve, there are several technical considerations during transcatheter aortic valve implantation (TAVI) when treating this subset of patients. We report a case of successful TAVI using a novel top-down deployment supra-annular leaflets valve in a patient with rheumatic aortic valve stenosis and mechanical mitral valve prosthesis.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.