Abstract

Severe aortic insufficiency with minimal aortic annular calcification has been considered a relative contraindication to transcatheter aortic valve implantation (TAVI) because of a lack of calcium for fluoroscopic visualization and radial stent fixation. We report a patient with severe aortic insufficiency after previous coronary artery bypass and aortic valve repair who underwent successful TAVI. Intraoperative transesophageal echocardiography was critical to guide valve implantation and previous surgical pledgets were used to seat an oversized TAVI prosthesis within the aortic annulus. In follow-up, the patient remained New York Heart Association class I and echocardiography demonstrated a well-functioning TAVI prosthesis with no aortic insufficiency.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.