Sonicated egg phosphatidylcholine vesicles loaded with 24Na+ were exposed at 20mW to a frequency-modulated (3 Hz) microwave field in the range of 2350 to 2550 MHz, or at 80 mW to a 2450-MHz CW (continuous wave) field, in a waveguide. The vesicle suspension absorbed microwaves at about 1 mW/ml and 25 mW/ml (CW experiment). The average temperature change of the irradiated suspension was less than 0.1 degree C from ambient. Leakage of 24Na+ from the vesicles for up to 19 hours was measured. No difference was noted in the movement of 24Na+ from the vesicles in the irradiated and control dispersions.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.