Abstract
ABSTRACT Objective To describe the approach of transabdominal ultrasound-guided oocyte retrieval in a patient of müllerian anomaly and ovarian malposition. Setting A tertiary referral reproductive medicine unit. Patient A 23-year-old patient with müllerian anomaly (right unicornuate with left rudimentary horn uterus) and ovarian malposition. Intervention Controlled ovarian hyperstimulation, transabdominal ultrasound-guided oocyte retrieval. Main outcome measure Total and mature oocytes retrieved, fertilization rate, embryo number and quality. Result Five oocytes were retrieved transabdominally using percutaneous needle puncture under ultrasound guidance. Conclusion In in vitro fertilization (IVF) protocols, patients with müllerian anomaly with inaccessible ovaries vaginally, transabdominal ultrasound-guided follicular aspiration is a safe and efficacious alternative technique for oocyte retrieval. How to cite this article Mishra VV, Choudhary S, Goyal PA, Aggarwal R. Transabdominal Ultrasound-guided Follicular Aspiration in Case of Müllerian Anomaly with Ovarian Malposition. J South Asian Feder Obst Gynae 2015;7(3):213-215.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of South Asian Federation of Obstetrics and Gynaecology
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.