Objective To explore the feasibility and application skills of transabdominal preperitoneal prosthesis (TAPP) with cross-encircling arms of mesh.Methods From Septemer 2009 to February 2012,46 cases were given TAPP with cross-encircling arms of mesh.The clinical data and surgery videos were retrospectively analyzed.Results All of the 46 cases with 53 inguinal hernias were successful in TAPP.The mean operative time of unilateral hernia was (57.74 ± 11.89) min,the mean operative time of 7 cases with biliateral hernia was (83.86 ±20.42) min and the longest time was 125 min.There were 6 cases with the contralateral hidden hernia,2 cases with hematoma,1 case with paresthesias of skin,no realpse.Conclusion The mesh with cross-encircling arms can be exactly fixed by spermatic cord,ductus deferens or round ligament of uterus,without stitching and stappling. Key words: Hernia, inguinal; Laparoscopies; Surgical procedures, operative; Mesh

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.