Abstract

<h3>Background Information</h3> Difficult Venous Access (DVA) patients are a frequent cause of increased preoperative pain scores, increased delays in Preop to OR times, and decreased patient satisfaction with their perioperative experience. Expert vascular access nurses (EVANs) have had little effect changing these key issues. Use of Trans-Illumination Devices (<b>TID</b>s) has demonstrated promising results in alieving some of these issues without increased risk to the patient. <h3>Objectives of Project</h3> The TID pilot was designed to improve patient safety, comfort and satisfaction while decreasing delays in the preoperative area relating to DVA patients. Staff satisfaction with TIDs data was measured through feedback on ease of use, procedure type, and success rates. <h3>Process of Implementation</h3> Staff education was required for the use of the ACCU VEIN red light LED TID. Training included a review of the equipment, proper distancing, settings, and cleaning for patient safety. Real time training was performed on live patients with verbal consent in the Prep and PACU. Data collection included patient Vascular Access Difficulty Level (VADL), number of insertion attempts, and the procedure performed. Post training satisfaction surveys were sent to nursing and clinical technicians to provide feedback on use of the TID. <h3>Statement of Successful Practice</h3> The ACCU VEIN TID was used on 70 patients. VADL A (55) and VADL B (15). It successfully reduced the number of insertion attempts in the DVA population (1<sup>st</sup> attempt=62, 2nd attempt=8). Calls for Anesthesia or EVANs were zero. The device gave real time information regarding the location and quality of veins being accessed. Reduction in number of insertion attempts decreased pain and improved patient satisfaction with IV starts. Staff graded the ACCU Vein ease of use (100%), being helpful (90%), and that they would use the device again (99%). <h3>Implications for Advancing the Practice of Perianesthesia Nursing</h3> Use of TIDs in areas where venous access is frequent will improve the quality of patient care and reduce the wait times associated with IV insertion of the DVA patient. Prep/PACUs, Infusion Centers, Emergency Departments, Phlebotomy, and IV therapy would all benefit having TIDs as standard equipment.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.