Abstract

Tranexamic acid (TA) as a synthetic derivative of lysine is a potent antifibrinolytic drug used to reduce bleeding during surgeries including dental extraction. The efficacy of TA administration in ovarian cancer and melasma has also been reported in a previous study. In this study, the mass spectral data set of TA as ethoxycarbonyl‐tert‐butyldimethylsilyl derivatives was newly constructed by gas chromatography‐tandem mass spectrometry in multiple reaction‐monitoring mode. This analytical method was validated with good linearity (r > 0.9988), limit of detection (LOD, 0.22 ng/mL), limit of quantification (LOQ, 0.72 ng/mL), relative standard deviation (1.3 to 4.8%), and relative error (−6.8 to 3.5%) under optimal conditions. The LOD and LOQ were assessed to be lower than other reported methods. Therefore, the present method will be useful for monitoring of TA in the pharmacological and cosmetic fields.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call