Abstract

Plasma-mediated ab interno trabeculectomy with the trabectome was first approved by the US Food and Drug Administration in 2004 for use in adult and pediatric glaucomas. Since then, increased clinical experience and updated outcome data have led to its expanded use, including a range of glaucomas and angle presentations, previously deemed to be relatively contraindicated. The main benefits are a high degree of safety, ease, and speed compared to traditional filtering surgery and tube shunts. The increasing burden of glaucoma and expanding life expectancy has resulted in demand for well-trained surgeons. In this article, we discuss the results of trabectome surgery in standard and nonstandard indications. We present training strategies of the surgical technique that include a pig eye model, and visualization exercises that can be performed before and at the conclusion of standard cataract surgery in patients who do not have glaucoma. We detail the mechanism of enhancing the conventional outflow pathway and describe methods of visualization and function testing.

Highlights

  • The trabecular meshwork (TM) is the main resistance of the conventional outflow route of aqueous humor in primary and - to an even greater extent - in secondary open angle glaucoma[1]

  • The main differences are the amount of access to angle structures measured in degrees of angle arc, method of TM removal (ablation in ab interno trabeculectomy (AIT) versus disruption), and whether an implant remains in the eye or not

  • Suture or catheter trabeculotomy in gonioscopy-assisted transluminal trabeculotomy (GATT) and Trab[360] (Sight Sciences, Menlo Park, CA, USA) can disrupt 360 degrees of TM through a single access site, whereas trabectome surgery (Neomedix Inc., Tustin, CA, USA) or goniotomy can achieve near 180 degrees of TM ablation or incision through a single clear corneal wound

Read more

Summary

23 Jan 2017 report

Washington University School of Medicine in St. Louis, St. Louis, USA. Any reports and responses or comments on the article can be found at the end of the article. This new version is published to remove some duplication of references in the Version 1 that were introduced during the Production stage

Introduction
Conclusions
26. Johnstone M
30. Brubaker RF
Findings
44. Sewall EC

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.