Abstract
Techniques have been developed to operate a low-pressure cloud chamber with pure water vapor. Photographs have been obtained of the tracks arising in this medium from the passage of ionizing radiation. The sources used were low-energy X rays, 242Cm alpha particles, and low-energy protons. Track lengths of the electrons were similar to those found previously in tissue-equivalent gas. W values of 35.6 +/- 0.4 and 32.6 +/- 0.6 eV per ion pair for carbon and aluminum X rays also compare closely with those in tissue-equivalent gas, but are somewhat higher than the predictions of Monte Carlo calculations. Differential w values were obtained: for alpha particles of energy 5.3 MeV the value was 33.0 +/- 3.0 eV per ion pair; for protons of energy 390, 230, and 85 keV the values were 30.6 +/- 1.9, 31.9 +/- 2.0, and 33.6 +/- 3.4 eV per ion pair. The energy losses of protons in water vapor were measured in a second (dummy) chamber used for energy calibration. Results support Janni's values of stopping power for protons in the energy range 40-480 keV.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.