Abstract
We have used a modification of the Blom-Singer technique in our last 24 tracheoesophageal punctures, performed on 20 patients. At the time of puncture a surgical stent with an indwelling Dacron polyester suture is placed to form the fistula. Forty-eight to 72 hours later the stent is backed out of the puncture site but the suture is allowed to remain. The Blom-Singer duckbill prosthesis is fitted and taped in the routine fashion. The suture is left to traverse the tracheoesophageal tract until the time of discharge, when it is removed. At discharge the patient is given a Silastic dilator, to be used if the puncture site becomes too small to allow for insertion of the duckbill prosthesis. Seventeen of the 20 patients in this group obtained good voice. Six operations would have been failures because of the loss of the patient's prosthesis in the immediate postoperative period if the modified technique had not been used.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.