THE USE of synthetic materials for reconstruction of the trachea presents some special problems in that the material should be airtight and also rigid enough to remain patent during inspiration. Various materials have been used in the past, including Marlex, skin grafts, stainless steel tubes, etc.1-4These have all had certain disadvantages, and the availability of silastic reinforced with Dacron suggested the possibility of using it for a tracheal graft. This is a translucent silicone rubber reinforced with dacron and is 0.040 inches thick. The material is very pliable and yet is rigid enough so that when it is rolled in tubular form it does not collapse. The sheet material can be rolled into any size and then glued (with RTV 732) in cylinder form either at the operating table or previously, and the material can then be autoclaved. It has very good suturing characteristics and seemed worthy of

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.