Abstract

To the Editor, We report a case involving a patient with an unanticipated difficult airway in whom tracheal intubation was achieved uneventfully by advancing a bronchoscope and a tracheal tube introducer through a LMA Supreme. The patient’s written consent was obtained for this publication. A 70 kg, 52-yr-old woman was scheduled for nephrolithotomy. She had an adequate mouth opening, a normal thyromental distance, and a Mallampati class 3 airway. Anesthesia was induced with midazolam, fentanyl, propofol, and atracurium iv. Adequate mask ventilation was achieved. Direct laryngoscopy with a Macintosh #3 blade showed a Cormack-Lehane Grade 3 laryngeal view and tracheal intubation failed in two attempts. After further mask ventilation, oral bronchoscopic (5.0 mm outer diameter [OD]) intubation was attempted but failed due to poor visualization from blood and secretions. The SPO2 decreased to 90%. A size 4 LMA Supreme (LMA International, Singapore) was inserted with a satisfactory capnographic waveform and SPO2 returned to 100%. A decision was then made to intubate the patient’s trachea via the LMA Supreme. A pediatric bronchoscope (Olympus BF XP60, 2.8 mm OD) operated by an anesthesiologist and a solid tracheal tube introducer with a coude tip (5 mm OD, Well Lead Medical, China) operated by a second anesthesiologist were advanced through the airway lumen of the LMA Supreme into the pharynx (Figure). The tracheal tube introducer was advanced under bronchoscopic guidance through the glottis into the trachea and positioned 3 cm above the carina. The bronchoscope and LMA Supreme were then removed while keeping the tracheal tube introducer in position. A 7.0 mm internal diameter (ID) tracheal tube was railroaded over the tracheal tube introducer and into the trachea, and positioning of the tracheal tube was confirmed by capnography. Ten minutes after the completion of surgery, the patient was awakened and the tracheal tube was removed. The patient’s recovery was uneventful. After failed attempts at tracheal intubation, a supraglottic airway may be inserted for lung ventilation while awaiting alternative airway equipment. In lieu of removing the supraglottic airway to attempt alternative intubation techniques, it can be kept in situ as a conduit for tracheal intubation. Ventilation is not interrupted and secretions and blood are kept posterior to the supraglottic airway allowing a clear path to the larynx. The LMA Supreme is a single-use variant of the LMA Proseal. Its curved shaft consists of a double lumen, i.e., a central lumen for gastric access within an airway lumen for respiratory tract access. Like the LMA Classic, it is difficult to pass an adequately sized endotracheal tube (ETT) directly through the LMA Supreme due to the airway luminal diameter. There are four techniques to achieve tracheal intubation with an adequately sized ETT, through the use of introducers or catheters, via the LMA Supreme. The four techniques utilize a small ETT, an Aintree Intubating Catheter, a guidewire, or a tracheal tube introducer. With the first technique, a small ETT (up to 6.0 mm ID) is mounted over a bronchoscope and inserted into the trachea through the LMA Supreme. Subsequently, an airway exchange catheter is inserted via the ETT, which is later exchanged for a full-sized ETT. Q.-J. Chu, MD X.-P. Han, MD First Affiliated Hospital, Zhengzhou University, Zhengzhou, China

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.