Abstract

An integrated on-line SPE–HPLC–MS/MS system has been developed for the rapid analysis of various trace level priority pesticides in surface and drinking water. Eleven pesticides were included in this study, with various phenylureas, triazines and organophosphorous species among them. Use of turbulent-flow chromatography columns (TFC, 50×1 mm, 30–50 μm particle size) as extraction cartridges enables fast on-line SPE at high sampling flow-rate (5 ml/min). Polymeric and carbon based TFC columns (Oasis HLB, Cyclone, Hypercarb) allow complete extraction with good recoveries from water volumes up to 50 ml. On-line coupling to HPLC is performed with re-mixing of the organic TFC eluate with water in front of the analytical column to ensure efficient band focussing. For fast HPLC analysis, a short monolithic column is applied in combination with highly selective API–MS/MS detection. Matrix effects on the APCI–MS/MS signal were found to be reduced by the system to an acceptable minimum. Limits of detection, determined for 10-ml samples of river water were in the range between 0.4 and 13 ng/l typically, except trifluralin (approximately 280 ng/l), which is less susceptible to ionization under atmospheric pressure conditions. At an enriched water volume of 10 ml, the whole SPE–HPLC–MS/MS procedure requires less than 14 min. The method was successfully applied to the analysis of drinking and surface water samples taken from several sampling sites around the city of Leipzig, Germany. Concentrations measured (maximum: 16 ng/l simazine in river water) were far below the concentration limits scheduled by law.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call