Abstract

The U.S. Nuclear Regulatory Commission (NRC) staff often performs confirmatory analysis to support regulatory decision making. In the current work the TRAC/RELAP Advanced Computational Engine (TRACE) code was used to study the transient system response for the NuScale power module to a beyond-design-basis event where the control rods fail to insert. The regulatory purpose of the current work was to confirm the results of analyses provided by the applicant as part of their probabilistic risk assessment analysis that demonstrates that the core is not damaged under certain conditions when the control rods fail to insert. The NRC staff performed calculations using a TRACE model of the NuScale power module that includes both the primary and secondary systems that simulates a loss of alternating-current power and complete failure of the module protection system to insert control rods. The NRC staff analyses demonstrate that under these conditions the reactor stabilizes at a new stable condition with minor power and pressure oscillations where core power is balanced by passive heat removal.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.