Abstract

A two-loop primary cooling system with a residual heat removal system was designed to mitigate the heat generated in the tungsten neutron source rods inside the rungs of the ladders and the shell of the rungs. The Transient Reactor Analysis Code (TRAC) was used to analyze the thermal-hydraulic behavior of the primary cooling system during a pump coastdown transient; a cold-leg, large-break loss-of-coolant accident (LBLOCA); a hot-leg LBLOCA; and a target downcomer LBLOCA. The TRAC analysis results showed that the heat generated in the tungsten neutron source rods can be mitigated by the primary cooling system for the pump coastdown transient and all the LBLOCAs except the target downcomer LBLOCA. For the target downcomer LBLOCA, a cavity flood system is required to fill the cavity with water at a level above the large fixed headers.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.