Abstract
A 66-year-old Chinese man developed corneal endothelial decompensation after intraocular lens (IOL) repositioning using intracameral epinephrine was performed. The presentation was compatible with toxic endothelial cell destruction syndrome, which is caused by prolonged, direct exposure of the corneal endothelium to relatively high concentrations of intracameral epinephrine. Despite its effective and immediate mydriatic effect, intracameral epinephrine is not recommended for intraoperative mydriasis in procedures such as IOL repositioning or secondary IOL implantation in which minimal irrigating solution is used.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.