Abstract

Modern gravitational-wave observatories require robust low-frequency active seismic isolation in order to keep the interferometer at its ideal operating conditions. Seismometers are used to measure both the motion of the ground and isolated platform. These devices are susceptible to contamination from ground tilt at frequencies below 0.1 Hz, particularly arising from wind-pressure acting on building walls. Consequently, during LIGO’s first observing run both observatories suffered significant downtime when wind-speeds were above 7 m s−1. We describe the use of ground rotation sensors at the LIGO Hanford Observatory to correct nearby ground seismometers to produce tilt-free ground translation signals. The use of these signals for sensor correction control improved low-frequency seismic isolation and allowed the observatory to operate under wind speeds as high as 15–20 m s−1.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.