AbstractRecent progress in materials characterization by sputter profiling is discussed, with particular emphasis on a critical evaluation of the parameters that determine the depth resolution. The net effect of beam‐induced material transport and sputtering can be studied in a straightforward manner using abrupt doping distributions embedded in the matrix of interest, parallel to its flat surface. It is shown that the quality of the data that can be obtained with modern instruments is sufficient to identify lack of sample quality in terms of either surface flatness or abruptness of the doping distributions. Except for the presence of special artefacts, the depth resolution is always improved by using as low a bombardment energy as possible. The optimum angle of beam incidence depends on the crystalline structure of the sample as well as on the chemical identity of the primary ions. With oxygen primary ions a rather complex situation is encountered. Compared to inert gas ions, an improvement or a degradation in depth resolution may be achieved, depending on the impurity–matrix system under study. The merits of sample rotation are also discussed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.