Abstract

The Tore Supra tokamak is the largest superconducting magnetic fusion facility, has been devoted to long-duration high-performance discharge research. With a steady-state magnetic field and water cooled plasma facing components, discharges up to 6 minutes 24 seconds duration with injected / extracted energy up to 1 GJ have been performed. The Tore Supra real time measurements and control (RTMC) system has been upgraded to address schemes dedicated to long pulse operation with simultaneous control of an increasing number of plasma parameters. This includes plasma equilibrium control with possible self calibration during the discharge, plasma density control with possible pellet injection, current profile control to avoid magneto-hydrodynamic (MHD) instabilities and infrared monitoring of plasma facing components preventing overheating. Most of these improvements are relevant to the tokamaks operation in a fully steady state regime.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.