Abstract

Volumetric tomography for combustion diagnostics is experiencing significant progress during the past few years due to its capability of imaging evolving turbulent flows. Such capability facilitates the understanding of the mechanisms behind complicated combustion phenomena such as lean blowout, acoustic oscillations, and formation of soot particles. However, these techniques are not flawless and suffer from high computational cost which prevents them from applications where real-time reconstructions and online monitoring are necessary. In this Letter, we propose a new reconstruction method that can effectively reduce the dimension of the inversion problem, which can then be solved with a minimum computational effort. This method and a classical iterative method were tested against each other using a proof-of-concept experiment in which endoscopic computed tomography of chemiluminescence (CTC) was implemented. The results show that the proposed method can dramatically reduce the computational time and, at the same time, maintain similar reconstruction accuracy, as opposed to the classical approach. Although this Letter was discussed under the context of CTC, it can be applied universally to other modalities of volumetric tomography such as volumetric laser-induced fluorescence.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call