Abstract

Robotic technology has been applied to atrial septal defect (ASD) repair for more than 10 years, but the number of cases reported is limited and results of long-term follow-up are not clear. This study reports on a large group of patients who underwent totally robotic ASD repair on an arrested or beating heart at a single institution with a 7-year follow-up. From 2007 to 2013, 160 patients (median age, 36 years; range, 11-66 years) at our centre underwent selective repair of secundum-type ASD using the da Vinci robotic system. The first 54 cases were performed on an arrested heart (arrested-heart group, n = 54) and the remainder on a beating heart (beating-heart group, n = 106). The mean diameter of defects was 2.9 cm (range, 1.1-4.1 cm). Cardiopulmonary bypass was achieved via cannulation of the femoral vessels and the right internal jugular vein. Blood cardioplegic arrest was induced using a transthoracic Chitwood clamp in the arrested-heart group. With the assistance of a robotic surgical system, atrial septal defect repairs were performed with or without tricuspid valvuloplasty via three 8-mm ports, a camera port and a working port in the right chest. Transoesophageal echocardiography was used to evaluate surgical results and follow-up. Complete ASD closure was verified by intraoperative transoesophageal echocardiography in all patients. None of the procedures was converted to an alternate technique and there were no major complications. There were significant learning curves for cross-clamp time, operative duration and cardiopulmonary bypass time. The beating-heart group had significantly shorter operative and cardiopulmonary bypass durations than the arrested-heart group (P = 0.000). The two groups had similar durations of mechanical ventilation and intensive care unit and hospital stays, and similar drainage volumes. During the 39 ± 21 months of follow-up, no patient required reoperation because of a residual shunt or tricuspid valve regurgitation. ASD can be performed safely and effectively on an arrested or beating heart with the assistance of robotic technology. This totally endoscopic approach represents an option for patients seeking a reliable, minimally invasive ASD repair with an excellent long-term result.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.