Abstract
The paper shows an experimental study to know the behaviour of tunnel magnetoresistive effect-based current sensors configured in a Wheatstone bridge in response to irradiation. In particular the sensitivity, hysteresis, output offset voltage and input resistance are discussed when the sensors are submitted to a total irradiation dose of 43krad with 36krad/h dose rate. The same electrical parameters were studied subsequently once the irradiated sensors were submitted to an 80°C annealing process. The studied TMR sensors are applied in a switched-mode power converter for space application.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.