Abstract

We report three cases of pseudotumoral lesion secondary to total hip replacement using metal on polyethylene bearings, presenting two distinct macroscopic aspects: (a) classic inflammatory granuloma and, in one case, (b) onset of hematoma associated with gluteal vessel lesions, probably affected by the pseudotumoral process. Diagnosis was radiographic, with CT-scan serving to confirm and, more importantly, to reveal extension and analyze surrounding tissue. Arteriography is needed when the lesion is liquid, and biopsy may be envisaged depending upon the clinical situation. In all three cases, histology was typically that of granulomatous lesions related to wear debris. Once diagnosis could be established, treatment was similar in both presentations, with surgical revision, which should be as early as possible in case of cortical bone involvement, to prevent pathologic fracture.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.