Abstract

Total hip arthroplasty (THA) after acetabular fracture presents unique challenges, including acetabular fixation. Twelve patients with a history of acetabular fracture underwent THA with porous metal cups. The average age was 57 years (range 24-88). THA was performed at an average 20 months from initial fracture. Average follow-up was 39 months (range 24-49). Average WOMAC scores improved from 32 to 79; UCLA scores improved from 1.75 to 5.25. There was one case of acetabular loosening in a renal transplant patient with rheumatoid arthritis. No other patients showed progressive radiolucent lines. At average three-year follow-up, porous metal components afforded improved clinical and radiographic outcomes in the majority of patients. Longer follow-up will determine whether porous metal is a durable option in the management of prior acetabular fracture.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.