Abstract

BackgroundWe investigated the mid-term clinical and radiological results of total hip arthroplasty (THA) using a three-dimensional (3D) porous titanium cup and analyzed the micromotion at the interface of the cup using subject-specific finite element (FE) analysis.MethodsWe evaluated 73 hips of 65 patients (6 men and 59 women; mean age at the time of surgery, 62.2 years; range, 45–86 years) who had undergone THA using a 3D porous titanium cup. Clinical evaluations were performed using the Japanese Orthopaedic Association (JOA) hip score system. We assessed the fixation of the acetabular component based on the presence of radiolucent lines and cup migration using anteroposterior radiographs. Subject-specific FE models were constructed from computed tomography data.ResultsThe JOA score improved from a preoperative mean of 52.2 (range, 23–82) to a mean of 87.8 (range, 71–100) at the final follow-up. None of the patients underwent revisions during the follow-up period. Radiolucent lines were observed in 26 cases (35.6%) and frequently appeared at DeLee and Charnley Zone 3. Following the FE analysis, the micromotion at DeLee and Charnley Zone 3 was significantly larger than that at Zone 2. Furthermore, micromotion was large in the groups in which radiolucent lines appeared at Zone 3.ConclusionsThe mid-term clinical outcome of THA using a 3D porous titanium cup was excellent. However, radiolucent lines frequently appeared at DeLee and Charnley Zone 3. FE analysis indicated that micromotion was large at the same site, strongly suggesting that it contributes to the emergence of radiolucent lines. The 3D porous titanium cups are useful in THA, and with improvements focused on micromotion, we anticipate better long-term outcomes.

Highlights

  • We investigated the mid-term clinical and radiological results of total hip arthroplasty (THA) using a three-dimensional (3D) porous titanium cup and analyzed the micromotion at the interface of the cup using subject-specific finite element (FE) analysis

  • Radiolucent lines frequently appeared at DeLee and Charnley Zone 3

  • FE analysis indicated that micromotion was large at the same site, strongly suggesting that it contributes to the emergence of radiolucent lines

Read more

Summary

Introduction

We investigated the mid-term clinical and radiological results of total hip arthroplasty (THA) using a three-dimensional (3D) porous titanium cup and analyzed the micromotion at the interface of the cup using subject-specific finite element (FE) analysis. According to national registration reports, the most common reason for revision surgery after total hip arthroplasty (THA) is aseptic loosening [1,2,3]. Scratch fit caused by a high friction coefficient suppresses micromotion [5, 13, 14] and higher porosity promotes bone infiltration into the interior of the porous region, resulting in long-term stability due to the interlocking of the acetabular component and bone [15]. In clinical reports of implants with a 3D porous structure, a high rate of radiolucent lines was observed [16,17,18]. Radiolucent lines are said to appear because of the fibrous fixation between the bone and components and occur with micromotion of ≥150 μm [19]

Methods
Results
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call